title: "Loft insulation calculator UK: rolls to 270 mm | BuildBatch"
description: "How many rolls of loft insulation do I need? A 6 × 5 m loft with 100 mm there now takes 4 rolls of 8.01 m² to reach at least 270 mm. Free UK calculator."
url: https://buildbatch.co.uk/loft-insulation-calculator/
---

# Loft insulation calculator

Mineral-wool rolls for a cold loft floor.

An example loft

## Insulating a 6 × 5 m loft to at least 270 mm, if 100 mm is there now

- **Insulation**: 4 rolls. 8.01 m² a roll · 31.5 m² needed. 0.54 m² left over

Built with AI tools; not yet checked by a tradesperson.

A 4.2 × 3.6 m loft with 100 mm there now takes 2 rolls of 170 mm insulation to reach 270 mm.

Want a figure before you measure? See [how many rolls of loft insulation a loft takes, by loft size](https://buildbatch.co.uk/examples/how-many-rolls-of-loft-insulation-by-loft-size/).

**Having it done, laying loft insulation:** labour only, £130 to £450 per day; with materials, £500 to £1,200 per loft; materials not stated, £654 to £1,206 per loft. These are published UK figures, each its publisher's own, and not a quote: [every figure and its source, on a page of their own: laying loft insulation](https://buildbatch.co.uk/costs/loft-insulation/).

**How the number is worked out, a worked example and questions**

## How the number is worked out

1. **Measure the loft floor.** Its length and width, or, for a floor that is not a rectangle, its area: split it into rectangles and add them up.
2. **Measure what is there.** Use the uncompressed depth of insulation that is in good condition.
3. **Choose the build-up.** Say how deep the insulation there now is, and enter the depth to reach and the thickness of the exact mineral-wool roll in “Change the figures”.
4. **Use the pack coverage.** BuildBatch multiplies the floor by the layers of each roll, adds the visible allowance, then rounds up to whole packs once for each roll. For a 100, 150, 170 or 200 mm roll it uses a typical figure, said so on the line: the square metres one roll of Knauf Loft Roll 44 Combi-Cut covers at that thickness, as the roll's product listings named it on 9 October 2026 (13.89, 9.18, 8.01 and 6.84 m²).

This is a material quantity, not a U-value or installation design. It does not decide whether the chosen product, depth or detail complies for your home.

**Where the figures come from.** The four roll coverages above are typical figures, read on 9 October 2026; each, with the page it was read on, is on the [sources page](https://buildbatch.co.uk/sources/#typical-loft-rolls). The depths and the 5% allowance in the worked example are examples, not a maker's figures or a design.

## A worked example

A 4.2 m × 3.6 m loft floor is 15.12 m². In the example, 100 mm is already present and one 170 mm layer reaches a chosen 270 mm target, with a visible allowance of 5%. One roll covers a typical 8.01 m²: Knauf Loft Roll 44 Combi-Cut at 170 mm, as the roll's product listings give it.

**Example depths and allowance; a typical roll coverage; not a design**

| Working | Figure | Result |
| --- | --- | --- |
| Loft floor | 15.12 m² | 100 mm |
| New layer and total | 1 × 170 mm | 270 mm |
| Layer area and 5% allowance | 15.12 m² | 15.876 m² |
| Divide by 8.01 m² and round up | **1.982022** | **2 packs** |

The exact roll width must also suit the joist spacing or top layer. Check the thickness and the square metres a pack covers on the exact product.

[Work it out for your room](https://buildbatch.co.uk/start/#v=1&job=loft&walls=none&ceiling=none&trim=none&units=m&length=4.2&width=3.6&surface=sound&subfloor=unsure&ground=unsure&fitting=unsure&loft=quick&end=13), starting from the example room's sizes.

## Stop and check first

- **Damp, leaks or poor ventilation.** Fix the cause and keep the eaves ventilation open.
- **Wiring and recessed lights.** Insulation can trap heat. Follow the equipment instructions and get electrical advice where needed.
- **Tanks and pipes.** A better-insulated loft is colder, so the water services need the right protection.
- **Boarding and access.** Do not compress deep insulation under boards. Any walkway or storage needs a suitable raised system and safe access.
- **Another roof type.** A room in the roof, insulation at rafter level, a flat roof, spray foam, loose fill and rigid boards are outside this calculation.

## Questions

**How much loft insulation do I need per m²?**

One square metre of roll for each square metre of loft floor, plus 5% for cuts: 15.876 m² of roll for a 15.12 m² loft, 2 packs of 170 mm to bring 100 mm up to 270 mm.

**Is 100 mm of loft insulation enough?**

270 mm is the common recommendation for mineral wool (the Energy Saving Trust's guide and UK scheme guidance), so a loft with 100 mm takes 1 × 170 mm more on top.

**Why does the example use 270 mm?**

The Energy Saving Trust's guide "How to insulate a loft" (linked from the loft insulation guide below) and current UK scheme guidance use 270 mm as a common mineral-wool recommendation. It is an editable example, not a claim that one depth is right for every roof, material or nation.

**What if there is no insulation?**

Enter 0 mm. The calculator counts enough equal layers of the chosen roll thickness to meet or pass your target, and shows the resulting installed depth.

**Can I use two different roll thicknesses?**

This page counts one roll thickness, in as many equal layers as reach the depth. A build-up in two thicknesses, one between the joists and one over them, is counted layer by layer: the floor's area with the allowance, divided by what a roll of each thickness covers. Another build-up needs the complete system design.

**Can I use it for a room in the roof?**

No. Insulation at rafters and sloping surfaces needs a different moisture, ventilation and thermal design.

## Related guides

- [How much loft insulation do I need?](https://buildbatch.co.uk/guides/how-much-loft-insulation-do-i-need/)
- [What you need to insulate a loft: the full list](https://buildbatch.co.uk/guides/what-you-need-to-insulate-a-loft/)
- [Square metres and square feet](https://buildbatch.co.uk/guides/square-metres-and-square-feet-for-rooms/)

Everything is worked out in your browser, and BuildBatch never sends the figures you type unless you sign in to an account and save a project. BuildBatch counts which tools are used, without a cookie. The insulation product, building guidance and safe installation plan come first. [How the estimates are worked out](https://buildbatch.co.uk/how-estimates-work/).